Home page | Brief introduction | News | Business range | Marketing networkRepresentative project | Contact us
   


Home page  Business Range>Machinery products



  • 产品名称: Rapid desorption electrowinning
  • 1.High temperature, high pressure, no-cyanide, auto-control of desorption, with features of high efficiency, low consumption and rapid.
    2.High-efficiency: when the grade of loaded carbon reaches 3000 g/t, the desorption rate can reach more than 96%, the barren carbon tenor with this equipment comparing with that of normal desorption electrowinning equipment will reduce by 50%-75%.
    3.Rapid:The temperature of desorption electrowinning can reach as high as 150℃ (generally 30~55℃ higher than in other kind system),and the working pressure of system can reach as high as 0.5Mpa(generally 0.2~0.5Mpa higher than in other kind system),so the desorption electrowinning is rapid with 12 hours typically (50%~75% time shortened).
    4.Low consumption: the same temperature for desorption, no need of heat-exchanging, working speed is rapid, power consumption is 1/2~1/4 of normal system.
    5.No cyanide: no need of adding NaCH into the desorption liquid; low cost; no pollution.
    6.High grade gold mud; no need of antielectrowinning; gold slurry extraction easy.
    7.Auto-control: the level-control system, temp-control system and auto-control system set specially.
    8.Safety: with 3 procedures of safety protection, the system itself intelligent, auto-limiting pressure and pressure releasing unit, safety valve.

    高效低耗快速解吸电解系统规格及选型推荐表

    Model Fitting size

    Equipment of the system in detail

    Instrument of the system in detail

    Operating parameter

    Mine size(t/d)

    Original ore tenor(g/t)

    GKJD-200

    <150

    2-8

    JXZ desorption

    column

    GLQ filter

    DJC electrowining tank

    CQ circulating pump

    DRQ electric heater

    W air compressor

    PYC desorption liquid tank

    XL controlling box

    GDF commutation box

     

    Electric resistance remote

    Transmission diaphragm pressure gauge

    Pressure indication adjusting meter

    Diaphragm pressure gauge

    Desorption liquid flow meter

    Flow integrating instrument

    Thermal temp meter

    Temp sensor

    Level meter

    Temp indication adjusting meter

     

     

    Temp:150±2(C)

    PH:≥13.5

    Flow:2.4(m3/h)

    Current:300±100(A)

    Electrowinning voltage:2-4(v)

    Rated power:75.6(kw)

    Desorption tank pressure:0.5-0.57(Mpa)

    Electrowinning tank pressure:0.45-0.52(Mpa)